Copper cables, symmetrical, twisted pair U / UTP cat.5e PE 4 (2) x2x0.51 (Lan-cable)

Symmetrical communication cables are designed for outdoor installation in telephone ducts, in collectors, mines, along the walls of buildings according to the international standard ISO / IEC 11801 and in broadband access networks in the frequency range up to 100 MHz with an operating voltage of no more than 75 V.

Design Brief

Weight and dimensions
Number of pairs
2
4
Nominal outer diameter, mm
5.1
5.35
Weight, kg / km
19.2
29.5
Copper core diameter
0.51mm (24 AWG)
Mechanical characteristics
Maximum tensile force
50 N
Sheath breaking force
not less than 9MPa
Bend radius
at least 8 diameters
Specifications
Name
Value
Operating frequency range, MHz
up to 100
Characteristic impedance in the frequency range (1-100) MHz, Ohm
100 ± 15
Intrinsic attenuation, dB / 100m, no more:
- at a frequency of 4 MHz
- at a frequency of 20 MHz
- at a frequency of 100 MHz

4.1
9.3
22.0
Crosstalk attenuation between circuits at the near end (NEXT), dB / 100m, not less:
- at a frequency of 4 MHz
- at a frequency of 20 MHz
- at a frequency of 100 MHz

56.3
45.8
35.3
Far end circuit security (FEXT), dB / 100m, not less than:
- at 4 MHz
- at 20 MHz
- at 100 MHz

52.0
38.0
24.0
Return loss (RL), dB / 100m, not less:
- at 4 MHz
- at 20 MHz
- at 100 MHz

23.0
25.0
20.1
Electric capacity of pairs, no more, nF / km
56

Performance Requirements

Cables may be operated at ambient temperatures: from minus 60 ° C to plus 60 ° C - for cables in a light-stabilized polyethylene sheath.

Inspection and installation of cables in a light-stabilized polyethylene sheath must be carried out at an ambient temperature of at least minus 20 ° C.

The bending radius of cables during installation must be at least eight of the maximum outer diameters of the cable.

Send a request
 
Your application has been sent.

Similar items:

Cable into the ground OKB-T

для прокладки в грунтах 1-3 групп, кабельной канализации, трубах, коллекторах, туннелях при наличии высоких требований по механической прочности

Manufacturer:

To order

Quantity

Upon request
Order Product

Sewer cable OKL-T

для прокладки в кабельной канализации, трубах, коллекторах, туннелях

Manufacturer:

To order

Quantity

Upon request
Order Product

Ground cable OKP

для прокладки в грунтах 1-5 групп, в кабельной канализации, туннелях, коллекторах, при наличии особо высоких требований по механической прочности и при особо высоких требованиях по устойчивости к внешним электромагнитным воздействиям

Manufacturer:

To order

Quantity

Upon request
Order Product

Soil cable OKBA-P

для прокладки ручным или механизированным способом в грунтах 1-3 групп, в кабельной канализации, трубах, блоках и коллекторах при наличии особо высоких требований по механической устойчивости, при пересечении рек и болот глубиной до 2м

Manufacturer:

To order

Quantity

Upon request
Order Product
Get CP
Request for direct purchase?*
Request for participation in the tender?*
Your application has been sent.