To order
Remote test unit designed to perform OTDR testing of optical fibers as stand-alone unit or in centrally managed monitoring sysme.
Technical parameters
Model |
DMET |
DCOR |
AMET |
ACOR |
CD03 |
CD10 |
CD11 |
CD13 |
CD16 |
NODE |
Central wavelength, nm |
1550±20 |
1570±20 | 1625±10 | 1650±5 | 1310±3 | 1490±3 | 1510±3 | 1550±3 | 1610±3 | 1625±3/1650±4 |
Acquisition mode |
OTDR | OTDR | OTDR | OTDR | OTDR | OTDR | OTDR | OTDR | OTDR | OTDR or iOLM |
Live port |
NO |
NO | YES | YES | YES | YES | YES | YES | YES | YES |
Event dead zone, m |
0,8 |
0,5 | ||||||||
Attenuation dead zone, m |
3,5 |
2 | ||||||||
Sampling points |
256000 |
|||||||||
Sampling resolution, m |
0,04-10 |
|||||||||
Pulse width, ns |
3-20000 |
|||||||||
Distance range, km |
1-320 |
|||||||||
Display resolution, dB |
0,001 - attenuation and loss / 0,01 - reflectance |
|||||||||
Dynamic range, dB |
42 |
46 | 42 | 43 | 41 | 41 | 41 | 41 | 41 | 35/33 |
Distance accuracy, m |
± (0,75 + 0,0025% * distance + sampling resolution) |
|||||||||
Connector type |
SC/APC or FC/APC |
|||||||||
Number of ports |
1, 4, 8, 12, 24 or 32 |
|||||||||
Control interface |
2 ports Ethernet 10/100/1000 Мbit/s |
|||||||||
Data storage, GB |
32 |
|||||||||
Power supply |
100-240 V 50-60 Hz АС or -40/-72 V DC |
|||||||||
Power consumption, W |
35 |
|||||||||
Rack type |
19”, 23” or ETSI |
|||||||||
Supproted browsers |
MS Internet ExplorerTM, Mozilla FireFoxTM, Google ChromeTM |
|||||||||
Operating temperature, °С |
-5 to +50 |
|||||||||
Storage temperature, °С |
-40 to +70 |
|||||||||
Relative humidity, % |
0-95 non-condensing |
|||||||||
Maximum altitude, m |
3000 |
|||||||||
Dimensions, mm |
2U: 88 x 435 x 270 |
|||||||||
Weight, kg |
8,7 (maximum) |
Specsheet download.
You request has been sent.